Interference Checker¶
Section Name [INTRCHECK]
AreaTolerance¶
Set Area tolerance(Valid for touch check mode)
positive real number value.
(Unit is mm.)
- Default Value: 0.1
CheckInroadSamplePointTol¶
Specify the tolerance for sample point creation for interference check.
Specify by a positive real number between 1e-6 to 1 (Unit: mm), or specify zero (0) to set an appropriate value automatically based on the model size.
This is effective only when “CheckMode=0”.
- Default Value: 0
CheckMode¶
Specify the check mode to use, interference check or touch check
- Default Value: 0
- Values
- 0: Interference check
- 1: Touch check
Clearance¶
Set tolerance of check.
Interference Check: Minimum distance threshold for interference. If distance is smaller than this, two part will be judged as interference.
Touch Check: Minimum distance threshold for touch. If distance is smaller than this, two part will be judged as touch.
real number value from 0 to 10000.0
- Default Value: 0
ExcludeNoShowElement¶
Specify whether to exclude hidden parts in checking interferences
- Default Value: 0
- Values
- 0: Check all parts including hidden parts
- 1: Exclude hidden parts in checking interferences
ReportAssemblyPath¶
Specify whether to include the assembly structure path to interfering parts in interference check result report in CSV format.
This is effective only when “CheckMode=0”.
- Default Value: 1
- Values
- 0: Don’t include assembly path
- 1: Include assembly path in CSV
ReportClearance¶
Specify whether to include the clearance value (the minimum distance between interfering parts) in the CSV report.
This is effective for Interference Check mode only.
- Default Value: 0
- Values
- 0: Don’t include the clearance value
- 1: Include the clearance value
ReportGravityPoint¶
Report gravity point information of interference (Valid for interference check mode)
- Default Value: 0
- Values
- 0: OFF
- 1: ON
ReportInstancePath¶
Specify whether to include the instance path to interfering instances in interference check result report in CSV format.
This is effective only when “CheckMode=0”.
- Default Value: 1
- Values
- 0: Don’t include instance path
- 1: Include instance path in CSV
ReportIntrDepth¶
Specify whether to include the depth of interference in interference check result report in CSV format.
This is effective only when “CheckMode=0”.
- Default Value: 0
- Values
- 0: Don’t include depth of interference
- 1: Include depth of interference in CSV
ReportIntrVolume¶
Specify whether to include the volume of interference in interference check result report in CSV format.
This is effective only when “CheckMode=0”.
- Default Value: 0
- Values
- 0: Don’t include volume of interference
- 1: Include volume of interference in CSV
ReportParameter¶
Specify whether to include the parameter information at the top of the CSV report.
This is effective for Interference Check mode only.
- Default Value: 1
- Values
- 0: Don’t include the parameter information
- 1: Include the parameter information at the top
SolidFlag¶
Specify check target element.
- Default Value: 0
- Values
- 0: check All faces
- 1: check only faces belongs to solid