Interference Checker

Section Name [INTRCHECK]

AreaTolerance

Set Area tolerance(Valid for touch check mode)
positive real number value.
(Unit is mm.)
  • Default Value: 0.1

CheckInroadSamplePointTol

Specify the tolerance for sample point creation for interference check.
Specify by a positive real number between 1e-6 to 1 (Unit: mm), or specify zero (0) to set an appropriate value automatically based on the model size.
This is effective only when “CheckMode=0”.
  • Default Value: 0

CheckMode

Specify the check mode to use, interference check or touch check

  • Default Value: 0
  • Values
    • 0: Interference check
    • 1: Touch check

Clearance

Set tolerance of check.
Interference Check: Minimum distance threshold for interference. If distance is smaller than this, two part will be judged as interference.
Touch Check: Minimum distance threshold for touch. If distance is smaller than this, two part will be judged as touch.
real number value from 0 to 10000.0
  • Default Value: 0

ExcludeNoShowElement

Specify whether to exclude hidden parts in checking interferences

  • Default Value: 0
  • Values
    • 0: Check all parts including hidden parts
    • 1: Exclude hidden parts in checking interferences

ReportAssemblyPath

Specify whether to include the assembly structure path to interfering parts in interference check result report in CSV format.
This is effective only when “CheckMode=0”.
  • Default Value: 1
  • Values
    • 0: Don’t include assembly path
    • 1: Include assembly path in CSV

ReportClearance

Specify whether to include the clearance value (the minimum distance between interfering parts) in the CSV report.
This is effective for Interference Check mode only.
  • Default Value: 0
  • Values
    • 0: Don’t include the clearance value
    • 1: Include the clearance value

ReportGravityPoint

Report gravity point information of interference (Valid for interference check mode)

  • Default Value: 0
  • Values
    • 0: OFF
    • 1: ON

ReportInstancePath

Specify whether to include the instance path to interfering instances in interference check result report in CSV format.
This is effective only when “CheckMode=0”.
  • Default Value: 1
  • Values
    • 0: Don’t include instance path
    • 1: Include instance path in CSV

ReportIntrDepth

Specify whether to include the depth of interference in interference check result report in CSV format.
This is effective only when “CheckMode=0”.
  • Default Value: 0
  • Values
    • 0: Don’t include depth of interference
    • 1: Include depth of interference in CSV

ReportIntrVolume

Specify whether to include the volume of interference in interference check result report in CSV format.
This is effective only when “CheckMode=0”.
  • Default Value: 0
  • Values
    • 0: Don’t include volume of interference
    • 1: Include volume of interference in CSV

ReportParameter

Specify whether to include the parameter information at the top of the CSV report.
This is effective for Interference Check mode only.
  • Default Value: 1
  • Values
    • 0: Don’t include the parameter information
    • 1: Include the parameter information at the top

SolidFlag

Specify check target element.

  • Default Value: 0
  • Values
    • 0: check All faces
    • 1: check only faces belongs to solid