|
1. Diagnosing Parts |
| Select the parts to diagnose. | |||||||||||||
Click [Parts] tab in the Check-Mate dialog box and select one of the following items:
|
|||||||||||||
![]() |
|||||||||||||
| There are 2 ways to specify an assemble model as a target:
|
|||||||||||||
| Select CADdoctor for NX Checker. | |||||||||||||
| After clicking the [Tests] tab, add [CADdoctor for NX Checker] from [Categories] to [Chosen Tests]. (With [CADdoctor for NX Checker] selected in [Categories], click the Add button or double-click [CADdoctor for NX Checker] to add it for testing.)
|
|||||||||||||
![]() |
|||||||||||||
| Specify customization | |||||||||||||
| (* Optional. Customize the settings only if you want to change the default settings.) After clicking the [Tests] tab, select [CADdoctor for NX Checker] in [Chosen Tests] and click the [Customize] button .
|
|||||||||||||
![]() |
|||||||||||||
| The following [Customization] dialog box appears. | |||||||||||||
![]() |
|||||||||||||
| The following options can be configured in the customization dialog box. | |||||||||||||
|
|||||||||||||
| Press [Configure Checker] button and following dialog opens. | |||||||||||||
![]() |
|||||||||||||
|
| |||||||||||||
| Specify execution options. | |||||||||||||
|
(* Optional. Customize the settings only if you want to change the default settings.) After clicking the [Run Options] tab, click the [Save Part After Checking] list and select [Save if Passed]. Additionally, select [Generate Check Flag] and [Treat Warning as Pass]. These settings make it possible to add a flag to the model which has passed all Standard Criteria. To save [Run Options] settings, save the settings on the [Run Options] tab by clicking the NX [File] menu and selecting [Utilities] - [Custom Defaults] - [Analysis] - [Check-Mate]. Note: If you selected [All Parts in Directory] on the [Parts] tab, reference points will not be saved if errors are detected. If you need reference points, click the [Save Part After Checking] list and select [Always Save]. |
|||||||||||||
![]() |
|||||||||||||
| Execute diagnostics. | |||||||||||||
Click to start diagnostics. |
|||||||||||||
|
A progress indicator appears after diagnostics begins. To cancel diagnostics currently underway, click the [Cancel] button. Note: Do not perform NX operations during diagnostics. |
|||||||||||||
![]() |
|||||||||||||
|
When processing is complete, the Check-Mate results dialog box will appear. The results are listed under [Results]. For instructions on investigating errors, see "Checking Error Positions." |
|||||||||||||
![]() |