| Results flag |
: |
Proof of data quality.
When the CADdoctor for NX Checker diagnostics to issue a Pass judgment (including passing with added information or warnings), the flag is appended to the part. |
Validity of the Results Flag
Check-Mate diagnostic results are invalidated if NX operations setting a part modification flag are performed (operations causing a [Modified] note to be displayed next to the part file name on the toolbar).
Specific examples of operations that invalidate checking results are given below:
| 1 |
All operations that change shapes |
| 2 |
Changing the rendering style (e.g., from shading to wireframe) |
| 3 |
Changing the status between constrained and unconstrained
|
| 4 |
Changing the colors of elements |
| 5 |
If editing mode is accessed via a history (even if no editing is done and the operation is ultimately canceled, an Invalid flag is set) |
| 6 |
Moving layers* |
| 7 |
Changing the status between shown and hidden** |
*Merely switching the active layer will not invalidate the guarantee. However, moving some element to another layer will invalidate the guarantee.
**Regarding switching to hidden: Even if an element is not actually hidden, merely receiving a Hide command will set an Invalid flag. (For Show commands, merely receiving a command will not set an Invalid flag.)
The validity of diagnostic results can be checked from the NX menu by selecting [Analysis] - [Check-Mate] - [Display Results Flag]. (See "4. Checking Results.")
|