2.Healing Error Elements Only |
This is an option for geometry healing: Heal the errored elements only.
(All the rest will remain as is.)
| Select the parts to heal. | |||||||||||||
Click [Parts] tab in the Check-Mate dialog box and select one of the following items:
|
|||||||||||||
| To specify an assemble model as a target, open top part of an assembly and select 'All Loaded Parts'. |
|||||||||||||
![]() |
|||||||||||||
| Run [CADdoctor for NX Checker(Nissan)] | |||||||||||||
| Run [CADdoctor for NX Checker(Nissan)] to check geometry errors. This is mandatory if you wish to perform geometry healing on errored elements only as it functions on detected error basis. Please note that this option works on the following errors only, which means nothing will be performed when detected errors are other than that.
|
|||||||||||||
![]() |
|||||||||||||
| Select CADdoctor for NX Partial Healer(Nissan). | |||||||||||||
| After clicking the [Tests] tab, add [CADdoctor for NX Partial Healer(Nissan)] from [Categories] to [Chosen Tests]. (With [CADdoctor for NX Partial Healer(Nissan)] selected in [Categories], click the Add button or double-click [CADdoctor for NX Partial Healer(Nissan)] to add it for testing.)
|
|||||||||||||
![]() |
|||||||||||||
| Specify customization | |||||||||||||
| (* Optional. Customize the settings only if you want to change the default settings.) After clicking the [Tests] tab, select [CADdoctor for NX Partial Healer(Nissan)] in [Chosen Tests] and click the [Customize] button
|
|||||||||||||
![]() |
|||||||||||||
| The following [Customization] dialog box appears. | |||||||||||||
![]() |
|||||||||||||
| The following options can be configured in the customization dialog box. | |||||||||||||
|
|||||||||||||
| Specify execution options. | |||||||||||||
|
(* Optional. Customize the settings only if you want to change the default settings.) After clicking the [Run Options] tab, click the [Save Part After Checking] list and select [Save if Passed], click the [Save Results to Teamcenter After Checking] list and select [Save if Passed]. Additionally, select [Generate Check Flag] and [Treat Warning as Pass]. These settings make it possible to save results to Teamcenter and to add a flag to the model which has passed all Standard Criteria. To save [Run Options] settings, save the settings on the [Run Options] tab by clicking the NX [File] menu and selecting [Utilities] - [Custom Defaults] - [Analysis] - [Check-Mate]. Note: If you selected [All Parts in Folder] on the [Parts] tab, reference points will not be saved if errors are detected. If you need reference points, click the [Save Part After Checking] list and select [Always Save]. |
|||||||||||||
![]() |
|||||||||||||
| Execute healing. | |||||||||||||
Click to start healing. |
|||||||||||||
|
A progress indicator appears after healing begins. To cancel healing currently underway, click the [Cancel] button. Note: Do not perform NX operations during healing. |
|||||||||||||
![]() |
|||||||||||||
| Please note that this may produce free edges. Click [Yes] in the warning dialog to continue. | |||||||||||||
|
When processing is complete, the Check-Mate results dialog box will appear. If checker is set to run after healing, the result of Checker will appear at once. For instructions on investigating errors, see "Checking Error Positions." |
|||||||||||||
![]() |
|||||||||||||
| [NOTE] With this option, original errored faces will be replaced by new faces created based on original faces, and then topological relation will be rebuilt by [SEW] command. In the event of success in sewing, bodies with new faces will be added to a feature group "SEW SUCCESS". In the event of failure in sewing, new faces will be suppressed, and bodies with new faces will be added to a feature group "SEW FAILURE". |