1.Healing Entire Part

This is an option for geometry healing: Heal the entire part(s) regardless of the check result.
(Geometry healing will be performed thoroughly including the area where no errors are detected.)

Select the parts to heal.
Click [Parts] tab in the Check-Mate dialog box and select one of the following items:
  • [Current Part]
  • ...To heal the part currently shown in the graphics window.
  • [All Loaded Parts]
  • ...To heal all parts currently loaded in NX.
  • [All Parts in Folder]
  • ...To heal all part files in the selected folder.

    To specify an assemble model as a target,
    open top part of an assembly and select 'All Loaded Parts'.
     
     
    Select CADdoctor for NX Healer(Nissan).
    Move to [Tests] tab. Select [CADdoctor for NX Healer(Nissan)] from [Categories] list, and click [Add] to add it to [Chosen Tests] list.
    You can also double-click to add it to [Chosen Tests] list.
     
    Specify customization
    (* Optional. Customize the settings only if you want to change the default settings.)

    After clicking the [Tests] tab, select [CADdoctor for NX Healer(Nissan)] in [Chosen Tests] and click the [Customize] button
     
    The following [Customization] dialog box appears.
     
    The following options can be configured in the customization dialog box.
    OptionDetails
    Configure Healer The tolerance used for the healing is settable.
    Press [Configure Healer] button and following dialog opens.
     
    Suppress or delete original model Select whether the original model shall be suppressed or deleted after healing.
    Generate csv log file Export files for healing results in CSV format. Files are produced in the specified folder with the filename [year (last two digits)] [month] [day] [hour] [minute] [second]_user name_heal.csv.
    Csv log file Directory Indicate the folder in which you want to save results files in CSV format. (This selection is valid only if you selected the [Generate csv log file] option.)
    Note: Folder names that include Japanese characters cannot be selected.
    Common Configuration Set common configuration of Checker and Healer.
    Press [Common Configuration] button and following dialog opens.
     

    Holding license time after process(sec) :
    If saving each part takes long time, specify larger value.
    Default value is 30.
     
    Specify execution options.
    (* Optional. Customize the settings only if you want to change the default settings.)

    After clicking the [Run Options] tab, click the [Save Part After Checking] list and select [Save if Passed], click the [Save Results to Teamcenter After Checking] list and select [Save if Passed]. Additionally, select [Generate Check Flag] and [Treat Warning as Pass]. These settings make it possible to save results to Teamcenter and to add a flag to the model which has passed all Standard Criteria.

    To save [Run Options] settings, save the settings on the [Run Options] tab by clicking the NX [File] menu and selecting [Utilities] - [Custom Defaults] - [Analysis] - [Check-Mate].

    Note: If you selected [All Parts in Folder] on the [Parts] tab, reference points will not be saved if errors are detected. If you need reference points, click the [Save Part After Checking] list and select [Always Save].
     
    Execute healing.
    Click to start healing.
     
    A progress indicator appears after healing begins.
    To cancel healing currently underway, click the [Cancel] button.

    Note: Do not perform NX operations during healing.
     
    When processing is complete, the Check-Mate results dialog box will appear. If checker is set to run after healing, the result of Checker will appear at once.
    For instructions on investigating errors, see "Checking Error Positions."