1. Diagnosing Parts


Select the parts to diagnose.
Click [Parts] tab in the Check-Mate dialog box and select one of the following items:
  • [Current Part]
  • ...To diagnose the part currently shown in the graphics window.
  • [All Loaded Parts]
  • ...To diagnose all parts currently loaded in NX.
  • [All Parts in Folder]
  • ...To diagnose all part files in the selected folder.

    To specify an assemble model as a target,
    open top part of an assembly and select 'All Loaded Parts'.
     
     
    Select CADdoctor for NX Checker(Nissan).
    After clicking the [Tests] tab, add [CADdoctor for NX Checker(Nissan)] from [Categories] to [Chosen Tests].
    (With [CADdoctor for NX Checker(Nissan)] selected in [Categories], click the Add button or double-click [CADdoctor for NX Checker(Nissan)] to add it for testing.)
     
    Specify customization
    (* Optional. Customize the settings only if you want to change the default settings.)

    After clicking the [Tests] tab, select [CADdoctor for NX Checker(Nissan)] in [Chosen Tests] and click the [Customize] button .
     
    The following [Customization] dialog box appears.
     
    The following options can be configured in the customization dialog box.
    OptionDetails
    Generate reference point Generate reference points in the NX model to identify the exact positions of errors.
    Generate csv log file Export files for checking results in CSV format. Files are produced in the specified folder with the filename [year (last two digits)] [month] [day] [hour] [minute] [second]_user name_PDQ.csv.
    Csv log file Directory Indicate the folder in which you want to save results files in CSV format. (This selection is valid only if you selected the [Generate csv log file] option.)
    Note: Folder names that include Japanese characters cannot be selected.
    Common Configuration Set common configuration of Checker and Healer.
    Press [Common Configuration] button and following dialog opens.
     

    Holding license time after process(sec) :
    If saving each part takes long time, specify larger value.
    Default value is 30.
     
    Specify execution options.
    (* Optional. Customize the settings only if you want to change the default settings.)

    After clicking the [Run Options] tab, click the [Save Part After Checking] list and select [Save if Passed], click the [Save Results to Teamcenter After Checking] list and select [Save if Passed]. Additionally, select [Generate Check Flag] and [Treat Warning as Pass]. These settings make it possible to save results to Teamcenter and to add a flag to the model which has passed all Standard Criteria.

    To save [Run Options] settings, save the settings on the [Run Options] tab by clicking the NX [File] menu and selecting [Utilities] - [Custom Defaults] - [Analysis] - [Check-Mate].

    Note: If you selected [All Parts in Folder] on the [Parts] tab, reference points will not be saved if errors are detected. If you need reference points, click the [Save Part After Checking] list and select [Always Save].
     
    Execute diagnostics.
    Click to start diagnostics.
     
    A progress indicator appears after diagnostics begins.
    To cancel diagnostics currently underway, click the [Cancel] button.

    Note: Do not perform NX operations during diagnostics.
     
    When processing is complete, the Check-Mate results dialog box will appear. The results are listed under [Results].
    For instructions on investigating errors, see "Checking Error Positions."